Pewaukee, WI – Static Regain Spiral Examples

February 04, 2012  |   News,Past Projects,Uncategorized   |     |   2 Comments

The attached photos show best practices for Spiral Static Regain and Seal Class A for all spiral.

Thanks to JF Ahern Co for an excellent installation example. This spiral ductwork with seal class A meets the ASHRAE 90.1-2010-6.4.4.2.1 requirements.

This project saved 22% of the ductwork cost using spiral static regain and is part of the 6 Job Savings chart in the NEWS section for the TRANE Strategic Partners Exchange.

 

 

 

 

 

 

 

2 Comments for this entry

    Blaine
    April 15th, 2020 on 6:25 pm

    Hi, very nice website, cheers!
    ——————————————————
    Need cheap and reliable hosting? Our shared plans start at $10 for an year and VPS plans for $6/Mo.
    ——————————————————
    Check here: https://www.reliable-webhosting.com/

    cialis
    May 13th, 2020 on 5:48 pm

    Definitely believe that which you said. Your favorite reason appeared
    to be on the internet the simplest thing to
    be aware of. I say to you, I certainly get irked while people consider worries that
    they just do not know about. You managed to hit the nail upon the top as well as defined out the whole thing without
    having side effect , people can take a signal.
    Will likely be back to get more. Thanks









Lastest News

  • Why using spiral duct improves duct design – SNIPS article
    April 22, 2019

    In 1948, research by R.G. Huebscher established flow resistance for different shapes of ductwork at equal velocities, which allowed the creation of the duct-sizing calculator or “Ductulator” for picking equivalent sizes of rectangular ducts based on the baseline round duct size. The Ductulator is a shortcut that only works on paper if you reduce the […]

  • 2014 was productive for Optimized Spiral using VariTRANE.
    December 30, 2014

    2014 was productive for Optimized Spiral using VariTRANE. A mechanical contractor in New Jersey used VariTRANE to save $80,000 cost on a 300T fitness center. A strategic partner in Utah used VariTRANE to save $70,000 cost on a 63,000 SF office building. A strategic partner in California used VariTRANE to save $60,000 cost on a […]

  • SPECIAL… BRING IT ON!
    July 27, 2012

    Guaranteed: $20,000 in engineered spiral static regain savings for preparing a redline system design up to 34,000 SF or 100 tons, a value of  $10,000. Included: a one-day static regain seminar at your location before December 14, 2015, Included: 12 months of support consultation by phone and email, a value of  $10,000 a value of    $7,500 a value of    $2,500 Total value […]

  • Trane Strategic Partner Exchange – 6 Real World Examples
    February 25, 2012